H&M Electric builds the essential electrical systems that keep hospitals, surgery centers, and imaging suites running around the clock. For more than two decades our teams have delivered code-critical power inside occupied Washington healthcare facilities without interrupting patient care.

Electrical rough-in and equipment power for a hospital electrophysiology procedure room

Essential electrical systems built to NFPA 99 and NEC Article 517

Healthcare electrical construction is defined by the codes that govern it. H&M Electric designs and installs essential electrical systems in strict conformance with NFPA 99 and NEC Article 517, separating the life-safety, critical, and equipment branches so that generators, transfer switches, and branch distribution behave predictably under fault and outage conditions.

Our field crews and project managers understand what the code language means at the device level: how quickly a transfer switch must restore power, where a branch may and may not be bonded, and how to keep the emergency system electrically and physically isolated from the normal source. That fluency is why general contractors and hospital facilities teams trust H&M with the branches that patient survival depends on.

Every installation is documented for the authority having jurisdiction and for the facility's own compliance record, so commissioning, inspection, and Joint Commission readiness proceed without surprises.

Isolated power for wet procedure locations

Operating rooms, hybrid ORs, and other wet procedure locations demand ungrounded isolated power systems with line isolation monitoring. H&M installs isolated power panels, reference grounding, and monitoring so that a single fault cannot interrupt a procedure or introduce a shock hazard around the patient.

We coordinate isolated power layouts with the surgical equipment, booms, and integration systems that share the room, and we test and document line isolation monitor performance before the space is turned over. The result is a procedure environment that meets code and gives clinical staff confidence in the power under their feet.

Imaging suites, EP labs, and cath labs

Diagnostic and interventional imaging is among the most demanding electrical work in the building. H&M has powered MRI, CT, and angiography suites, electrophysiology labs, and cardiac catheterization labs where equipment power quality, grounding, and shielding coordination are non-negotiable.

MRI rooms in particular require close collaboration with the vendor and the RF shield contractor: penetrations, waveguides, filtered power, and quench-vent-adjacent conduit routing all have to be resolved before rough-in. We plan these interfaces early so the magnet arrives to a room that is ready for it.

For EP and cath labs, we bring dedicated equipment branch power, isolated grounding references, and precise coordination with the imaging gantry, hemodynamic systems, and boom-mounted displays. Our experience across multiple Puget Sound imaging and interventional projects means fewer field conflicts and a cleaner startup.

ICRA and phasing inside occupied facilities

Most healthcare work happens in a live building with patients on the other side of the wall. H&M plans and executes to Infection Control Risk Assessment (ICRA) requirements, maintaining barriers, negative pressure, and clean routing so construction dust and activity never reach patient areas — and, where the work affects life-safety systems, to the facility's Interim Life Safety Measures (ILSM) so egress, alarm, and suppression coverage stay intact.

We sequence outages, temporary power, and cutovers with the facilities team so that critical branches are never dark, and we perform disruptive work in off-hours windows when a department can be safely taken down. Careful phasing is what lets a hospital keep operating while a wing, floor, or suite is rebuilt around it.

Healthcare electrical capabilities

From the generator plant to the procedure-room receptacle, H&M self-performs the code-critical scope that hospital projects hinge on.

Essential electrical systems

Life-safety, critical, and equipment branch distribution built to NFPA 99 and NEC Article 517, with generators, ATS, and emergency feeders coordinated end to end.

Isolated power systems

Ungrounded isolated power panels and line isolation monitoring for operating rooms, hybrid ORs, and other wet procedure locations.

MRI & imaging suites

Filtered power, grounding, and shield-coordination for MRI, CT, and angiography, planned with the equipment vendor and RF shield contractor.

EP & cath labs

Dedicated equipment power, isolated grounding, and tight coordination with imaging gantries, hemodynamic systems, and boom-mounted displays.

ICRA & infection control

Construction executed to ICRA protocols with barriers, negative pressure, and clean routing that protect adjacent patient areas.

Occupied-facility phasing

Sequenced outages, temporary power, and after-hours cutovers that keep critical branches energized while departments stay in service.

Serving Washington since
1993Serving Washington since
In healthcare & critical environments
20+ yrsIn healthcare & critical environments
Essential electrical systems built to code
NFPA 99Essential electrical systems built to code
Emergency response, within one day
24/7Emergency response, within one day

Related work

All projects
Fully equipped hospital operating room with ceiling-mounted surgical booms, integrated monitors, and isolated power systems installed by H&M ElectricHealthcare & Critical Environments
Seattle, WA

Surgery center — operating rooms, PACU & sterile core

Fully equipped operating rooms with surgical booms and integrated power, plus post-anesthesia recovery (PACU) and a sterile processing core — the essential electrical systems a surgical suite depends on.

Operating roomsSurgical boomsPACU
Electrophysiology (EP) lab with a ceiling-mounted imaging system, cardiac monitors, and isolated power wired by H&M ElectricHealthcare & Critical Environments
Seattle, WA

Heart & vascular center — EP and cath labs

Electrophysiology and cardiac catheterization labs with ceiling-mounted imaging systems, isolated power, and the equipotential grounding these interventional-cardiology spaces require.

EP labCath labImaging system
Banks of underground electrical conduit rough-in sweeping through rebar for a radiation oncology linear accelerator (LINAC) vaultHealthcare & Critical Environments
Seattle, WA

Radiation oncology — linear accelerator (LINAC) vault

Underground conduit rough-in and power distribution for a shielded linear-accelerator vault — high-stakes coordination beneath the concrete radiation shielding of an oncology suite.

LINAC vaultRadiation oncologyUnderground conduit
Healthcare & Critical Environments
Bellevue, WA

Hospital imaging & surgical center — EP labs, CT, MRI

Multi-phase work across a major hospital campus: electrophysiology labs, CT scanner and MRI suites, and an outpatient surgery center — executed in an occupied, operating facility.

EP labsCT scannerMRI suite
Healthcare & Critical Environments
Burien, WA

Hospital CT, angiography & RF room build-out

Phased CT installation, angiography suite, an RF-shielded room, and mechanical HVAC power upgrades within an active hospital.

CT scannerAngiographyRF-shielded room

Frequently asked

Questions buyers ask us

What makes an electrical contractor qualified for hospital work?

Hospital electrical work requires fluency in NFPA 99 and NEC Article 517, the ability to build and separate the life-safety, critical, and equipment branches, and disciplined execution inside occupied facilities under ICRA. H&M has delivered this scope across Puget Sound healthcare projects for more than two decades.

Do you install isolated power systems for operating rooms?

Yes. We install ungrounded isolated power panels, reference grounding, and line isolation monitoring for operating rooms, hybrid ORs, and other wet procedure locations, and we test and document monitor performance before turnover.

Can you power MRI, CT, and angiography suites?

We power MRI, CT, and angiography imaging suites, coordinating filtered power, grounding, penetrations, and shielding with the equipment vendor and RF shield contractor so the room is ready when the equipment arrives.

How do you keep a hospital running during construction?

We plan to ICRA requirements, maintain infection-control barriers, and sequence outages, temporary power, and cutovers with the facilities team. Disruptive work is performed in off-hours windows so critical branches stay energized and patient care continues.

What healthcare facilities does H&M serve?

We serve hospitals, ambulatory surgery centers, imaging centers, EP and cath labs, and radiation oncology and specialty clinics throughout Washington, with concentrated work across Snohomish and King counties.

Bid invitations & estimates

Planning a hospital or imaging project? Let's talk scope.

We work with general contractors, healthcare facilities, developers, and property managers across Washington. Send plans and we'll respond quickly.

24/7 ServiceRequest an Estimate